Kombi boiler PREDATOR 25 KW PELLET

Kombi boiler PREDATOR P 25 kW

Kusové dřevo
Kusové dřevo
Dřevěné pelety
Dřevěné pelety
KOMBINOVANÝ KOTEL PREDATOR P 25 KW
kovarson certifikaty

The Czech PREDATOR combination boilers provide economical and environmentally-friendly heating for houses, business premises and medium-large buildings, and offer heating water as well. The boilers comprise a combination of a gasification boiler for wood, chips or briquettes, and an automatic boiler for pellets. The combustion chamber takes pieces of wood up to 55cm long!

The combination boilers meet emission class 5 per EN 303-5, which are the strictest values for emissions released from a boiler into the atmosphere. This combustion system is also highly economical, achieving savings of up to 40% compared to ordinary wood-burning boilers. The boilers achieve efficiency levels of up to 90%!

The large-capacity storage containers for pellets and the 135 litre storage containers for wood make the boilers easy to use in both manual and automatic mode, with high efficiency levels. With manual operation, the feeding chamber is large enough for about 8 to 12 hours of heating at medium output. In energy-saving mode the boiler will keep going for up to 24 hours. In automatic mode the contents of the storage container will last for 4 days and in energy-saving mode up to 10 days. The boilers must be connected to a storage tank. We recommend a tank of about 40 litres for every 1 kW of boiler output. The heat energy can be used for several days, depending on the size of the tank. The boilers can be controlled by a room thermostat which regulated the mixing valve and switches off the central heating pump as required.

BOILER DESIGN

The inner boiler body is welded from high quality 6mm boiler plate. We use 8mm plate for the most stressed and critical parts. The plate for the outer body is 4 mm thick. The feeding chamber is fitted with 3 mm stainless steel inserts. They protect the boiler from

 

condensates and tar, prolonging its working life. The upper part houses the feeding chamber, which has a refractory concrete section at the bottom with a nozzle for the gas to go through. The hot gases pass through the concrete to a burn-out area made of vermiculite and refractory concrete. The main heat exchanger tube with walls 6.1 mm thick lines the rear wall of the boiler, with the upper part opening into a collection channel, after which the cooled gases go out to the chimney. The tubes are fitted with turbulators for easy, problem-free cleaning.

 

BOILER PROTECTION

Boilers must be connected to a storage vessel in order to allow any excess energy to escape to store heat energy. Protection is also provided at the boiler outlet by a thermostat which shuts off the fan, switches on all pumps and opens all of the mixing valves when the temperature passes the 95°C mark. The cooling loop is an additional feature. If the boiler temperature passes the 95°C mark, the cooling loop's bimetal thermostat opens a valve, releasing cold water into the boiler from the water supply and draining hot water from the other side.

BOILER OPERATION:

Burning is encouraged by an exhaust fan which blows primary air into the feeding chamber and secondary air into the nozzle. The wood is gasified in the upper feeding chamber, producing wood gas. The wood gas is sucked into the nozzle by the secondary air and burned in the space below the nozzle. The hot gases then pass through the main rear heat exchanger tube, where they transfer most of their energy, and the cooled

In automatic mode, combustion is encouraged by a fan in universal burners, the fuel is supplied using an electric motor and the exhaust fan must always operate at minimum speed. All of the material is combusted in the burner and the hot gases go straight to the rear main heat exchanger tube, where they transfer most of their energy, and the cooled gases go out through a collection tube to the chimney.

The boilers are fitted with an exhaust fan which goes to full speed after the feeding door is opened, and sucks all of the smoke into the chimney through the air chamber located above the feeding chamber so that it does not get into the boiler room. Cleaning a boiler with turbulators using the handle on the side of the boiler. Lifting the turbulators causes any deposits to fall down from the tubes into the ashtray area. The cleaning can be performed on both the right and the left side of the boiler. The ash remaining in the feeding chamber can be collected through the ignition doors. The rest of the ash can be collected through the lower ashtray openings.

 

UNIVERSAL BURNER:

The boilers are fitted with a 35 kW universal burner consisting of a cast-iron furnace, air mixing chamber and feeder. The feeder screw is made of metal and runs along the entire length of the feeder right up to the furnace and is fitted with an opposing thread where it meets the furnace, forcing the material upwards as required. This get rids of any sinter, which is forced out through the sides into the ashtray. Thanks to its extended shaft, the feeder is firmly anchored on both sides and makes no squeaking noises during operation. The burners take wood pellets. Thanks to the square shape and drawing in of air from four sides to the centre to encourage combustion, the burners achieve high combustion temperatures and efficiency levels.

BOILER REGULATION

The FOX temperature regulator is designed for combination boilers fitted with a screw feeder with fan and an exhaust fan for the wood gas. It controls the central heating pump, hot water pump, underfloor heating pump, mixing valve pump, burner fan and fuel feeder. The regulator includes a control module for one mixing valve. The device can work with more mixing valves (with the help of additional modules), traditional room regulators (two-position ones) or with RS communications, GSM modules and Internet modules.

       This regulator has the advantage of being very easy to use. The user makes all changes to parameters from the control unit.  Another advantage is the large and well-arranged graphic display, where users can see the exact operating state of the boiler at any given moment. The FOX regulator provides an interrupted output signal. With this type of regulator, the fan speed is set by measuring the temperature of the boiler and of the flue gases at the boiler outlet.

        Using this type of regulator with a flue gas temperature sensor brings fuel savings of over twenty percent; the water output temperature is very stable, and this prolongs the life of the heat exchanger (boiler). Controlling the temperature of the flue gases at the boiler outlet results in low emissions of harmful gases. Heat energy from the flue gases is not wasted, but used to heat water.

CERTIFICATES
INSTRUCTIONS
LEAFLETS
GRANTS
Označení kotle   PREDATOR 25
Jmenovitý výkon na dřevo kW 25
Jmenovitý výkon na pelety kW 25
Minimální výkon na pelety kW 8
Účinnost dřevo % 92
Účinnost pelety jmenovitý výkon % 92
Teplota spalin dřevo °C 87,3
Teplota spalin pelety -jmenovitý výkon °C 124,4
Teplota spalin pelety -minimální výkon °C 60,4
Tah Komína ps 20
Doporučená provozní teplota topné vody °C 70 - 90
Minimální teplota vratné vody °C 55
Připojovací napětí V 230
Elektrický příkon W 60
Hmotnost celková kg 827
Hmotnost kotlového tělesa kg 500
Obsah vodního prostoru l 140
Objem spalovací komory na dřevo dm3 135,5
Objem zásobníku na pelety l 350
Hloubka spalovací komory na dřevo mm 550
Rozměr plnícího otvoru zásobníku na dřevo mm 440x300
Rozměr plnícího otvoru zásobníku na uhlí mm 370x335
Hloubka kotle  mm 1200
Výška kotle mm 1700
Šířka kotle mm 1400
Průměr kouřového hrdla mm 160
Přípojky topné a vratné vody 6/4
řída kotle dle ČSN EN 303-5 dřevo/pelety   5
Vytápěná plocha do: m2 250